
Chapter 3 Operation
69
(5) EtherNet/IP Type Status LED
: Illuminating
: OFF
: Flashing
Name
Lamp
condition
Color
Description
In operation condition and under control of
scanner (master)
Green
Setting of construction information incomplete, or
scanner (master) in idling condition
Fatal malfunction (exception condition or critical
error)
MS
Orange
Light malfunction possible to recover
Online status
(Connection established on one or more)
Green
Online status (connection not being established)
Critical error such as IP address duplication
NS
Orange
Timeout in connection on one or more
(6) Simple Absolute Status LED Lamps (PC/PG/PCF/PGF type)
: Illuminating
: OFF
: Flashing
Name
Lamp
condition
Color
Description
Green Battery fully charged
Orange Battery in charge
0
Red
Battery not connected
Name
Lamp Condition of 1
(Color)
Lamp Condition of 2
(Color)
Description
(Green)
(Green)
Absolute reset complete
(Red)
(Green)
Absolute reset incomplete
1, 2
-
(Red)
Alarm
Содержание MSEL
Страница 1: ...MSEL Controller Instruction Manual Fifth Edition ...
Страница 2: ......
Страница 4: ......
Страница 30: ...22 ...
Страница 44: ...Chapter 1 Specifications Check 36 ...
Страница 102: ...Chapter 4 Home Return Absolute Reset 94 ...
Страница 232: ......
Страница 233: ......