(2) Output Port Function Allocation
Parameter
Output
Function
Select
No.
No.
Set Value
Function of an Input Signal
At the
delivery
0
Universal output
1
Error output at the operation cancellation level or more (ON)
2
Error output at the operation cancellation level or more (OFF)
3
Error output at the operation cancellation level or more +
emergency-stop output (ON)
4
Error output at the operation cancellation level or more +
emergency-stop output (OFF)
7
Output of an error of maintenance information alert function
related message level (Error No. 231 or 232) (ON)
300
No.46
8
Output of an error of maintenance information alert function
related message level (Error No. 231 or 232) (OFF)
0
Universal output
1
READY output (PIO trigger program operation available)
2
READY output (PIO trigger program operation available) and
without occurrence of any error at the operation cancellation
level or more
301
No.47
3
READY output (PIO trigger program operation available, and
without occurrence of any error at the cold start level or more)
0
Universal output
1
Emergency-stop output (ON)
302
No.48
2
Emergency-stop output (OFF)
0
Universal output
1
AUTO mode
303
No.49
2
Output during automatic operation (Other parameter No. 12)
0
Universal output
1
Output when all the effective axes at home position (= 0)
2
Output when home-return operation on all the effective axes
in complete condition (coordinates confirmed)
304
No.50
3
Output when all the effective axes in home preset coordinates
0
Universal output
1
1
st
axis in-position output (OFF when miss-pressing)
305
No.51
2
Output while the 1
st
axis servo is ON (system monitoring task
output)
0
Universal output
1
2
nd
axis in-position output (OFF when miss-pressing)
306
No.52
2
Output while the 2
nd
axis servo is ON (system monitoring task
output)
0
Universal output
1
3
rd
axis in-position output (OFF when miss-pressing)
307
No.53
2
Output while the 3
rd
axis servo is ON (system monitoring task
output)
0
Universal output
1
4
th
axis in-position output (OFF when miss-pressing)
308
No.54
2
Output while the 4
th
axis servo is ON (system monitoring task
output)
309
No.55
0
Universal output
310
No.56
0
Universal output
311
No.57
0
Universal output
312
No.58
0
Universal output
313
No.59
0
Universal output
314
No.60
0
Universal output
315
No.61
0
Universal output
Содержание MSEL