Chapter 5 I/O Parameter
97
5.1 I/O Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
1 I/O port assignment type
0
0 ~ 20
0: Fixed assignment
2
Input port start number at I/O1
affixed assignment
000
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
3
Output port start number at
I/O1 affixed assignment
300
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
4 System reservation
0H
0H ~ FFFFFFFFH
5 System reservation
0H
0H ~ FFFFFFFFH
6 System reservation
0H
0H ~ FFFFFFFFH
7 System reservation
0H
0H ~ FFFFFFFFH
8 System reservation
0H
0H ~ FFFFFFFFH
9 System reservation
0H
0H ~ FFFFFFFFH
10 I/O error monitor
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor
(Do not monitor errors relating to 24-V I/O power source)
3: Monitor
(Monitor only errors relating to 24-V I/O power source)
* Some exceptions apply.
* If 0 (= Do not monitor) or 2 (= Monitor (Monitor only errors
relating to 24-V I/O power sours)) is selected, a system
error wlii not generate even when an abnomallity relating
to the 24-V I/O power source occurs. However,
allsubsequent actual outputs from the digital I/O board
will be cut off by a circuit to protect the controller.
11 System reservation
0H
0H ~ FFFFFFFFH
12 System reservation
0H
0H ~ FFFFFFFFH
13 System reservation
0H
0H ~ FFFFFFFFH
14
Number of I/O2 fieldbus
remote input used ports
0
0 ~ 240
Multiple of 8
15
Number of I/O2 fieldbus
remote output used ports
0
0 ~ 240
Multiple of 8
16
Input port start number at I/O2
affixed assignment
48
-1 ~ 299
0 + (Multiple of 8) (Invalid if a negative value is set)
17
Output port start number at
I/O2 affixed assignment
348
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
18 I/O2 error monitor
1
0 ~ 5
0: Do not monitor
1: Monitor
* Some exceptions apply.
19 (For extension)
0
20 Input filtering periods
2
1 ~ 9
msec
Input signal is recognized when the status is held for twice
the period set by this parameter.
21 Register input filtering periods
2
1 ~ 9
msec
Input signal is recognized when the status is held for twice
the period set by this parameter.
22 System reservation
2000
0 ~ 99999
msec
23 System reservation
0H
0H ~ FFFFFFFFH
24 System reservation
0
0H ~ FFFFFFFFH
25 (For extension)
0
26 (For extension)
0
27 (For extension)
0
28 (For extension)
0
29 (For extension)
0
30 Input function selection 000
1
0 ~ 5
0: General-purpose input
1: Program start signal (ON edge) (007 to 014,
BCD-specified program number)
2: Program start signal (ON edge) (007 to 014,
Binary-specified program number)
* When using this signal to start a program, make sure the
signal remains ON to 100 msec or longer so that the
program will start without fail.
Note: The port number assigned to this function can be
changed using I/O Parameter No. 283, “Physical
input port number for input function selection 000”.
31 Input function selection 001
0
0 ~ 5
0: General-purpose input
1: Software reset signal (1 second ON)
* If continued operation is specified as the action upon
emergency stop, enable the software reset signal (to
provide a means of canceling the operation).
Note: The port number assigned to this function can be
changed using I/O Parameter No. 284, “Physical
input port number for input function selection 001.”