Chapter 6
Troubleshooting
174
In the panel window, the error numbers follow E in the display.
Error No.
Error name
Description, action, etc.
B81
Each axis PTP multiple axes
indication error
Each axis PTP operation on multiple axes was indicated.
Each axis PTP operation is available to indicate only one
axis.
* It is an error only for SCARA
B82
Jog multiple axes indication error Jog and inching operations are indicated on several axes.
Jog and inching operations are available only on one axis.
B84
Arm length error
There is an error in the arm length.
C
heck in “Each Axis
Parameter No. 138 Arm Length”.
* It is an error only for SCARA
B85
Operation start position
acquirement error in application
servo use work area
The operation start position in the application servo use
work area cannot be acquired.
B86
SEL PTRQ command
preprocessing error
The PTRQ command setting is abnormal. Check the
setting for abnormality, such as deviation from the
allowable range.
B87
Target tracking in tool datum point
keep-out circle error
The target position or the track of the movement is in the
tool datum point keep-out circle.
* It is an error only for SCARA
B88
Logic error in effective target data
calculation
Internal logic error has been issued during effective target
data calculation.
B89
SCARA CP logic error
Internal logic error was detected during SCARA CP
process.
* It is an error only for SCARA
B8C
Simple interference check zone
violation detection (Operation
cancel level indication)
There was an invasion detected in the simple interference
check zone. (Operation cancel level indication)
* It is an error only for SCARA
B8F
Positioning time calculation error Positioning time calculation error was occurred.
* It is an error only for SCARA
B90
Transmit distance calculation
error
Transmit distance calculation error was occurred.
* It is an error only for SCARA
Operatio
n-can
cellati
on l
evel
errors
B91
Main excessive speed demand
error
Excessive speed is demanded. It may also occur when
passing near the singularity in CP Operation. In CP
Operation, avoid passing near the singularity when in
programming. It may also be avoided by decreasing the
indicated speed.
* It is an error only for SCARA