Chapter 6
Troubleshooting
182
In the panel window, the error numbers follow E in the display.
Error No.
Error name
Description, action, etc.
CCA Arch top/end-point reversing error The coordinates of highest point and end point are
reversed during arch motion operation.
CCB Arch start-point/trigger reversing
error
The coordinates of start point and start-point arch trigger
are reversed during arch motion operation.
CCC Arch end-point/trigger reversing
error
The coordinates of end point and end-point arch trigger
are reversed during arch motion operation.
CCD Drive-source cutoff axis use error An attempt was made to use an axis whose drive source
is cut off.
CCE Error axis use error
An attempt was made to use an axis currently generating
an error.
Operatio
n-can
cellati
on
le
vel
errors
CCF Palletizing
reference-point/
valid-axis mismatch error
The PX/PY (/PZ)-axes set by PASE/PCHZ are not valid in
the axis pattern of the reference-point data set by PAST.