FAULT CODE
204
Flash code FI warning
lamp (MIL)
37
FI
warning lamp (
MIL
) flashes 3x long, 7x short
Display on diagnostic tool
P0351
"Cylinder 1 ignition coil"
"Malfunction in the circuit"
Error level condition
Malfunction in the circuit.
The engine will be switched off:
≥
0.2 s
Function check
Checking the ignition coil (
Possible cause
Ignition coil - value not plausible (
Injection coil - control line has a short circuit to ground (terminal 31) (
Ignition coil - control line has a short circuit to sensor ground (
Ignition coil - control line has a short circuit to plus (terminal 30) (
Ignition coil - control line has a short circuit to ignition plus (terminal 15) (
Ignition coil - control line is open (
Checking the ignition coil
Condition
The diagnostic tool is connected and active.
–
Select the model type.
–
Select
"ECU Diagnostic"
.
–
Highlight the
"Engine electronics EXC"
control unit.
–
Press
"Continue"
.
–
Select
"actuator test"
.
–
"Please enter password:"
–
Press
"Continue"
.
–
Select
"Ignition cylinder 1"
.
–
Press
"Continue"
.
–
Read the information page in the HUSABERG diagnostic tool and, with
"Continue"
, begin the actuator test.
Spark plug
Function noise
» If the specification is attained:
–
Delete the fault code.
–
Make a test ride.
–
Read out the fault code.
» If the specification is not attained:
–
Check the next possible cause:
Ignition coil - value not plausible (
Ignition coil - value not plausible
Condition
The control line of the ignition coil is disconnected.
400601-10
Ignition coil - check the resistance
–
Measure the resistance between the specified points.
Ignition coil Pin
1
–
Ignition coil Pin
2
Ignition coil
Primary winding resistance at: 20 °C
(68 °F)
0.425… 0.575
Ω
» If the measured value does not correspond to the specified value:
–
Change the ignition coil.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Injection coil - control line has a short circuit to ground (terminal 31)
Содержание FE 450 AUS
Страница 2: ......
Страница 205: ...FAULT CODE 203 If the measured value corresponds to the specified value Contact customer service...
Страница 237: ...235...
Страница 243: ...WIRING DIAGRAM 241...
Страница 247: ...WIRING DIAGRAM 245...
Страница 253: ...WIRING DIAGRAM 251...
Страница 261: ...WIRING DIAGRAM 259...