![HUSABERG FE 450 AUS Скачать руководство пользователя страница 207](http://html1.mh-extra.com/html/husaberg/fe-450-aus/fe-450-aus_repair-manual_2187561207.webp)
FAULT CODE
205
Injection coil - control line has a short circuit to ground (terminal 31)
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The control line of the ignition coil is disconnected.
600849-01
400607-11
Ignition coil - check the control line for a short circuit to ground (terminal 31)
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
18
–
measuring point
Ground(
−
)
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
18
to pin
1
of the ignition coil for a short circuit to ground (terminal 31).
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Ignition coil - control line has a short circuit to sensor ground (
Ignition coil - control line has a short circuit to sensor ground
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The control line of the ignition coil is disconnected.
600849-01
Ignition coil - checking the control line for a short circuit to sensor ground
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
18
–
Break Out Box
DT
Pin
24
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
18
to pin
1
of the ignition coil for a
short circuit to sensor ground.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Ignition coil - control line has a short circuit to plus (terminal 30) (
Ignition coil - control line has a short circuit to plus (terminal 30)
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The control line of the ignition coil is disconnected.