![HUSABERG FE 450 AUS Скачать руководство пользователя страница 218](http://html1.mh-extra.com/html/husaberg/fe-450-aus/fe-450-aus_repair-manual_2187561218.webp)
FAULT CODE
216
Flash code FI warning
lamp (MIL)
15
FI
warning lamp (
MIL
) flashes 1x long, 5x short
Display on diagnostic tool
P1632
"Rollover sensor (A/D type)"
"Input signal too high"
Error level condition
Voltage
"(A/D type)"
:
≥
4.57 V
Time:
≥
3 s
Voltage
"(A/D type)"
: 1.875… 3.125 V
Time:
≥
25.5 s
Function check
Checking the rollover sensor (
Possible cause
Rollover sensor - signal line has a short circuit to plus (terminal 30) (
Rollover sensor - signal line has a short circuit to ignition plus (terminal 15) (
Rollover sensor - signal line has a short circuit to the sensor power supply (
Rollover sensor - signal line is open (
Rollover sensor - ground line is open (
Checking the rollover sensor
Condition
The diagnostic tool is connected and active.
–
Select the model type.
–
Select
"ECU Diagnostic"
.
–
Highlight the
"Engine electronics EXC"
control unit.
–
Press
"Continue"
.
–
Select
"Measurement values"
.
–
Highlight
"Starter"
.
–
Press
"Continue"
.
–
Highlight the measured value
"Rollover sensor voltage (RolloverAD)"
and deselect the other parameters with
"Select measured value"
.
Info
Deselecting the other parameters improves the quality of the selected parameters (faster data transmission due to smaller
data volume).
Roll angle sensor
Voltage
"Standard"
0.4… 1.4 V
Voltage
"Drop detected"
3.7… 4.1 V
» If the displayed value is equal to the setpoint value:
–
Delete the fault code.
–
Make a test ride.
–
Read out the fault code.
» If the displayed value is above the setpoint value:
–
Check the next possible cause:
Rollover sensor - signal line has a short circuit to plus (terminal 30) (
Rollover sensor - signal line has a short circuit to plus (terminal 30)
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The rollover sensor is disconnected.