FAULT CODE
178
Intake air temperature sensor - value not plausible
Condition
Th e diagnostic tool is disconnected.
The breakout box is connected to the wiring harness.
600849-01
Intake air temperature sensor - check the resistance
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
24
–
Break Out Box
DT
Pin
25
Intake air temperature sensor
Resistance at:
−
20 °C (
−
4 °F)
18.80 k
Ω
Resistance at: 20 °C (68 °F)
2.942 k
Ω
Resistance at: 40 °C (104 °F)
1.136 k
Ω
Resistance at: 100 °C (212 °F)
0.1553 k
Ω
» If the measured value does not correspond to the specified value:
–
Change the intake air temperature sensor.
» If the measured value corresponds to the specified value:
–
Contact customer service.