FAULT CODE
197
Injection valve - control line has a short circuit to ignition plus (terminal 15)
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The injection valve is disconnected.
600849-01
Injection valve - check the control line for a short circuit to ignition plus (terminal 15)
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
1
–
Break Out Box
DT
Pin
16
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
16
to connector
DQ
pin
2
for a short cir-
cuit to ignition plus (terminal 15).
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Injection valve - control line has a short circuit to the sensor power supply
Injection valve - control line has a short circuit to the sensor power supply
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The injection valve is disconnected.
600849-01
Injection valve - check the control line for a short circuit to the sensor power supply
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
13
–
Break Out Box
DT
Pin
16
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
16
to connector
DQ
pin
2
for a short cir-
cuit to the sensor power supply.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Injection valve - control line is open (
Injection valve - control line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The injection valve is disconnected.
600849-01
400591-10
Injection valve - check the control line for an open circuit
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
16
–
Connector
DQ
Pin
2
Resistance
≤
0.6
Ω
» If the measured value does not correspond to the specified value:
Содержание FE 450 AUS