FAULT CODE
183
–
Check the next possible cause:
Coolant temperature sensor - signal line has a short circuit to the sensor power
supply (
Coolant temperature sensor - signal line has a short circuit to the sensor power supply
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Coolant temperature sensor is disconnected.
600849-01
Coolant temperature sensor - check the signal line for a short circuit to the sensor power
supply
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
13
–
Break Out Box
DT
Pin
22
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
22
to connector
AX
pin
1
for a short cir-
cuit to the sensor power supply.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Coolant temperature sensor - signal line is open (
Coolant temperature sensor - signal line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Coolant temperature sensor is disconnected.
600849-01
400586-10
Coolant temperature sensor - check the signal line for an open circuit
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
22
–
Connector
AX
Pin
1
Resistance
≤
0.6
Ω
» If the measured value does not correspond to the specified value:
–
Check connector
DT
pin
22
and connector
AX
pin
1
.
–
Check the cable from connector
DT
pin
22
to connector
AX
pin
1
for an open circuit.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Coolant temperature sensor - ground line is open (
Coolant temperature sensor - ground line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Coolant temperature sensor is disconnected.
Содержание FE 450 AUS