![HUSABERG FE 450 AUS Скачать руководство пользователя страница 177](http://html1.mh-extra.com/html/husaberg/fe-450-aus/fe-450-aus_repair-manual_2187561177.webp)
FAULT CODE
175
Flash code FI warning
lamp (MIL)
13
FI
warning lamp (
MIL
) flashes 1x long, 3x short
Display on diagnostic tool
P0113
"Intake air temperature sensor"
"Input signal too high"
Error level condition
Intake air temperature sensor voltage
"TAAD"
:
≥
4.824 V
Time:
≥
3 s
Function check
Intake air temperature sensor - checking the voltage (
Possible cause
Intake air temperature sensor - signal line has a short circuit to plus (terminal 30) (
Intake air temperature sensor - signal line has a short circuit to ignition plus (terminal 15)
Intake air temperature sensor - signal line has a short circuit to the sensor power supply
Intake air temperature sensor - signal line is open (
Intake air temperature sensor - ground line is open (
Intake air temperature sensor - value not plausible (
Intake air temperature sensor - checking the voltage
Condition
The diagnostic tool is connected and active.
–
Select the model type.
–
Select
"ECU Diagnostic"
.
–
Highlight the
"Engine electronics EXC"
control unit.
–
Press
"Continue"
.
–
Select
"Measurement values"
.
–
Highlight
"Mixture preparation, general"
.
–
Press
"Continue"
.
–
Highlight the measured value
"Intake air temperature sensor voltage (TAAD)"
and deselect the other parameters with
"Select mea-
sured value"
.
Intake air temperature sensor voltage
"TAAD"
0.196… 4.823 V
» If the displayed value is equal to the setpoint value:
–
Delete the fault code.
–
Make a test ride.
–
Read out the fault code.
» If the displayed value is above the setpoint value:
–
Check the next possible cause:
Intake air temperature sensor - signal line has a short circuit to plus (terminal 30) (
Intake air temperature sensor - signal line has a short circuit to plus (terminal 30)
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.