FAULT CODE
209
Fuel pump - control line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Fuel pump is disconnected.
600849-01
400593-10
Fuel pump - check the control line for an open circuit
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
15
–
Connector
DV
Pin
2
Resistance
≤
0.6
Ω
» If the measured value does not correspond to the specified value:
–
Check connector
DT
pin
15
and connector
DV
pin
2
.
–
Check the cable from connector
DT
pin
15
to connector
DV
pin
2
for an open circuit.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Fuel pump - resistance of ground line is too high (
Fuel pump - resistance of ground line is too high
Condition
Th e diagnostic tool is disconnected.
Fuel pump is disconnected.
400593-10
400607-11
Fuel pump - check the load capacity of the ground line
–
Measure the voltage between the specified points.
Connector
DV
Pin
1
–
measuring point
Plus (+)
Info
For the measurement, the measurement points must be loaded with a 12V/21W bulb.
The value should not vary more than 1V from the battery voltage
"VBAT"
.
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DV
pin
1
to the next node in the cable harness for an open circuit.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Fuel pump - control line has a short circuit to ground (terminal 31) (