FAULT CODE
168
Flash code FI warning
lamp (MIL)
09
FI
warning lamp (
MIL
) flashes 9x short
Display on diagnostic tool
P0107
"Manifold absolute pressure sensor cylinder 1"
"Input signal too low"
Error level condition
Manifold absolute pressure sensor voltage
"PM1AD"
:
≤
0.215 V
Time:
≥
3 s
Function check
Manifold absolute pressure sensor - checking the voltage (
Possible cause
Manifold absolute pressure sensor - signal line has a short circuit to sensor ground (
Manifold absolute pressure sensor - signal line has a short circuit to ground (terminal 31)
Manifold absolute pressure sensor - power supply is open (
Manifold absolute pressure sensor - checking the voltage
Condition
The diagnostic tool is connected and active.
The engine is not running.
–
Select the model type.
–
Select
"ECU Diagnostic"
.
–
Highlight the
"Engine electronics EXC"
control unit.
–
Press
"Continue"
.
–
Select
"Measurement values"
.
–
Highlight
"Mixture preparation, general"
.
–
Press
"Continue"
.
–
Highlight the measured value
"Manifold absolute pressure sensor cylinder 1 voltage (PM1AD)"
and deselect the other parameters with
"Select measured value"
.
Manifold absolute pressure sensor voltage
"PM1AD"
at: 800 mbar (11.6 psi)
2.31 V
at: 850 mbar (12.33 psi)
2.45 V
at: 900 mbar (13.05 psi)
2.58 V
at: 1,000 mbar (14.5 psi)
2.86 V
at: 1,050 mbar (15.23 psi)
2.99 V
» If the displayed value is equal to the setpoint value:
–
Delete the fault code.
–
Make a test ride.
–
Read out the fault code.
» If the displayed value is below the setpoint value:
–
Check the next possible cause:
Manifold absolute pressure sensor - signal line has a short circuit to sensor ground (
Manifold absolute pressure sensor - signal line has a short circuit to sensor ground
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The manifold absolute pressure sensor is disconnected.
400595-10
Manifold absolute pressure sensor - check the signal line for a short circuit to sensor ground
–
Measure the resistance between the specified points.
Connector
DX
Pin
2
–
Connector
DX
Pin
3
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DX
pin
2
to connector
DT
pin
6
for a short cir-
cuit to sensor ground.