![HUSABERG FE 450 AUS Скачать руководство пользователя страница 196](http://html1.mh-extra.com/html/husaberg/fe-450-aus/fe-450-aus_repair-manual_2187561196.webp)
FAULT CODE
194
600849-01
400588-10
Intake air temperature sensor - check the signal line for an open circuit
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
7
–
Connector
CU
Pin
2
Resistance
≤
0.6
Ω
» If the measured value does not correspond to the specified value:
–
Check connector
DT
pin
7
and connector
CU
pin
2
.
–
Check the cable from connector
DT
pin
7
to connector
CU
pin
2
for an open circuit.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Lambda probe - ground line is open (
Lambda probe - ground line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Lambda sensor is disconnected.
600849-01
400588-10
Lambda probe - check the ground line for an open circuit
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
24
–
Connector
CU
Pin
1
Resistance
≤
0.6
Ω
» If the measured value does not correspond to the specified value:
–
Check connector
DT
pin
24
and connector
CU
pin
1
.
–
Check the cable from connector
DT
pin
24
to connector
CU
pin
1
for an open circuit.
» If the measured value corresponds to the specified value:
–
Contact customer service.