![HUSABERG FE 450 AUS Скачать руководство пользователя страница 202](http://html1.mh-extra.com/html/husaberg/fe-450-aus/fe-450-aus_repair-manual_2187561202.webp)
FAULT CODE
200
Ignition pulse generator - signal lines are open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Ignition pulse generator is connected.
600849-01
Ignition pulse generator - check the signal lines for an open circuit
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
3
–
Break Out Box
DT
Pin
9
Pulse generator
Resistance at: 20 °C (68 °F)
80… 120
Ω
» If the measured value does not correspond to the specified value:
–
Check connector
DT
pin
3
and connector pin
9
.
–
Check connector
AL
pin
1
and connector pin
2
.
–
Check the cable from connector
DT
pin
3
to connector
AL
pin
2
for an open cir-
cuit.
–
Check the cable from connector
DT
pin
9
to connector
AL
pin
1
for an open cir-
cuit.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Ignition pulse generator - signal lines have a short circuit to each other
Ignition pulse generator - signal lines have a short circuit to each other
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Ignition pulse generator is connected.
600849-01
Ignition pulse generator - check the signal lines for a short circuit to each other
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
3
–
Break Out Box
DT
Pin
9
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
3
to connector
AL
pin
2
for a short cir-
cuit to the cable from connector
DT
pin
9
to connector
AL
pin
1
.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Ignition pulse generator - signal lines have a short circuit to ground (termi-
nal 31) (
Ignition pulse generator - signal lines have a short circuit to ground (terminal 31)
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Ignition pulse generator is connected.
Содержание FE 450 AUS
Страница 2: ......
Страница 205: ...FAULT CODE 203 If the measured value corresponds to the specified value Contact customer service...
Страница 237: ...235...
Страница 243: ...WIRING DIAGRAM 241...
Страница 247: ...WIRING DIAGRAM 245...
Страница 253: ...WIRING DIAGRAM 251...
Страница 261: ...WIRING DIAGRAM 259...