![HUSABERG FE 450 AUS Скачать руководство пользователя страница 182](http://html1.mh-extra.com/html/husaberg/fe-450-aus/fe-450-aus_repair-manual_2187561182.webp)
FAULT CODE
180
Resistance at: 90 °C (194 °F)
216… 264
Ω
Resistance at: 100 °C (212 °F)
165… 202
Ω
Resistance at: 110 °C (230 °F)
128… 156
Ω
Resistance at: 120 °C (248 °F)
100… 122
Ω
» If the measured value does not correspond to the specified value:
–
Change the coolant temperature sensor.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Coolant temperature sensor - signal line has a short circuit to ground (termi-
nal 31) (
Coolant temperature sensor - signal line has a short circuit to ground (terminal 31)
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Coolant temperature sensor is disconnected.
600849-01
400607-11
Coolant temperature sensor - check the signal line for a short circuit to ground (terminal 31)
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
22
–
measuring point
Ground(
−
)
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
22
to connector
AX
pin
1
for a short circuit to ground (terminal 31).
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Coolant temperature sensor - signal line has a short circuit to sensor ground (
Coolant temperature sensor - signal line has a short circuit to sensor ground
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Coolant temperature sensor is disconnected.
600849-01
Coolant temperature sensor - check the signal line for a short circuit to sensor ground
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
22
–
Break Out Box
DT
Pin
24
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
22
to connector
AX
pin
1
for a short cir-
cuit to sensor ground.
» If the measured value corresponds to the specified value:
–
Contact customer service.
Содержание FE 450 AUS
Страница 2: ......
Страница 205: ...FAULT CODE 203 If the measured value corresponds to the specified value Contact customer service...
Страница 237: ...235...
Страница 243: ...WIRING DIAGRAM 241...
Страница 247: ...WIRING DIAGRAM 245...
Страница 253: ...WIRING DIAGRAM 251...
Страница 261: ...WIRING DIAGRAM 259...