FAULT CODE
218
Rollover sensor - signal line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The rollover sensor is disconnected.
600849-01
400583-10
Rollover sensor - check the signal line for an open circuit
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
2
–
Connector
AP
Pin
5
Resistance
≤
0.6
Ω
» If the measured value does not correspond to the specified value:
–
Check connector
DT
pin
2
and connector
AP
pin
5
.
–
Check the cable from connector
DT
pin
25
to connector
AP
pin
5
for an open circuit.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Rollover sensor - ground line is open (
Rollover sensor - ground line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The rollover sensor is disconnected.
600849-01
400583-10
Rollover sensor - check the ground line for an open circuit
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
24
–
Connector
AP
Pin
4
Resistance
≤
0.6
Ω
» If the measured value does not correspond to the specified value:
–
Check connector
DT
pin
24
and connector
AP
pin
4
.
–
Check the cable from connector
DT
pin
24
to connector
AP
pin
4
for an open circuit.
» If the measured value corresponds to the specified value:
–
Contact customer service.