![HP HPE iLO 5 Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/hp/hpe-ilo-5/hpe-ilo-5_user-manual_164420053.webp)
•
Not Available
—The component is not available or not installed.
•
Degraded
—The device or subsystem is operating at a reduced capacity.
iLO displays the power supply status as
Degraded
when mismatched power supplies are installed.
If you power on a server with nonredundant fans or power supplies, the system health status is listed
as
OK
. However, if a redundant fan or power supply fails while the system is powered on, the system
health status is listed as
Degraded
until you replace the fan or power supply.
•
Failed Redundant
—The device or subsystem is in a nonoperational state.
•
Failed
—One or more components of the device or subsystem are nonoperational.
•
Other
—For more information, navigate to the
System Information
page of the component that is
reporting this status.
•
Link Down
—The network link is down.
•
Unknown
—The iLO firmware has not received data about the device status. If iLO was reset when
the server was powered off, some subsystems display the status
Unknown
because the status cannot
be updated when the server is powered off.
•
Not Installed
—The subsystem or device is not installed.
Viewing processor information
The
Processor Information
page displays the available processor slots, the type of processor installed
in each slot, and a summary of the processor subsystem.
If the server is powered off, the system health information on this page is current as of the last power off.
Health information is updated only when the server is powered on and POST is complete.
Procedure
Click
System Information
in the navigation tree, and then click the
Processors
tab.
Processor details
The following information is displayed for each processor:
•
Processor Name
—The name of the processor.
•
Processor Status
—The health status of the processor.
•
Processor Speed
—The speed of the processor.
•
Execution Technology
—Information about the processor cores and threads.
•
Memory Technology
—The processor memory capabilities.
•
Internal L1 cache
—The L1 cache size.
•
Internal L2 cache
—The L2 cache size.
•
Internal L3 cache
—The L3 cache size.
Viewing processor information
53