Test alerts are used to verify the network connectivity of iLO with the
Trap Destination(s)
addresses.
After the alert is generated, check the alert destination for receipt of the alert.
5.
To save the configuration, click
Apply
.
SNMP traps
lists the SNMP traps that you can generate with iLO 5 and supported ProLiant servers and
Synergy compute modules.
Table 3: SNMP traps
Trap
number
Trap name
Description
0
Cold Start Trap
SNMP has been initialized, the system
has completed POST, or AMS has
started.
4
Authentication Failure Trap
SNMP has detected an authentication
failure.
1006
cpqSeCpuStatusChange
An uncorrectable machine check
exception has been detected in a
processor.
1010
cpqSeUSBStorageDeviceReadErrorOccurred
A read error occurred on an attached
USB storage device.
1011
cpqSeUSBStorageDeviceWriteErrorOccurred
A write error occurred on an attached
USB storage device.
1012
cpqSeUSBStorageDeviceRedundancyLost
USB storage device redundancy was
lost.
1013
cpqSeUSBStorageDeviceRedundancyRestored
USB storage device redundancy was
restored.
1014
cpqSeUSBStorageDeviceSyncFailed
The sync operation to restore USB
storage device redundancy failed.
1015
cpqSePCIeDiskTemperatureFailed
The temperature of the PCIe disk
crossed the upper critical threshold.
1016
cpqSePCIeDiskTemperatureOk
The temperature of the PCIe disk is
normal.
1017
cpqSePCIeDiskConditionChange
The status of the PCIe disk changed.
1018
cpqSePCIeDiskWearStatusChange
The PCIe disk wear status changed.
1019
cpqSePciDeviceAddedOrPoweredOn
A PCI disk was added or powered on.
Table Continued