Embedded Smart Array
The installed Smart Array firmware version. This value is displayed only if server POST has
successfully completed since the last auxiliary power cycle.
iLO IPv4
The iLO IPv4 address. This value is displayed only if
Show iLO IP during POST
is enabled on the
Access Settings
page.
iLO IPv6
The iLO IPv6 address. This value is displayed only if
Show iLO IP during POST
is enabled on the
Access Settings
page.
iLO Hostname
The iLO hostname.
Critical Log Entries
The most recent
Critical
events from the IML are displayed, with the most recent event displayed
first.
Event log entries
For a list of the errors that might appear in the iLO Event Log, see the error messages guide for your
server at the following website:
.
Incorrect time stamp on iLO Event Log entries
Symptom
iLO Event Log entries have an incorrect date or time.
Cause
The NTP server addresses or the time zone is configured incorrectly.
Action
Verify that the SNTP settings are configured correctly.
USB key attached to iLO Service Port fails to mount
Symptom
A USB key attached to the iLO Service Port fails to mount.
Cause
The USB key is not formatted in FAT32 format or it has an invalid partition table.
Action
• Verify that the USB key is formatted to FAT32. If not, reformat the USB key.
• If the USB key is formatted to FAT32, and will not mount, use a utility such as Microsoft DiskPart to
delete and recreate the partition.
364
Event log entries