Error messages 99
Temperature violation detected - system Shutting Down in x seconds
Audible Beeps
: 1 long, 1 short
Possible Cause
: The system has reached a cautionary temperature level and is shutting down in
X
seconds.
Action
: Adjust the ambient temperature, install fans, or replace any failed fans.
There must be a first DIMM in pair if second DIMM in pair is populated. Second DIMM in pair
ignored.
Description
: The first DIMM socket in the pair is not populated. The second DIMM in the pair is not
recognized or used.
Action:
Populate the DIMM socket.
This system only supports 667 MHz Front Side Bus Speed Processors. One or more 800 MHz
Front Side Bus Speed Processors have been initialized at 667 MHz. System Halted!
Audible beeps
: 1 long, 1 short
Possible cause
: One or more 800-MHz front side bus speed processors have been initialized at 667-
MHz.
Action
: Correct the processor configuration.
Unsupported DIMM(s) found in system. - DIMM(s) may not be used
Description
: Unsupported memory types found in system.
Action:
Refer to the applicable server user guide memory requirements and replace with supported
DIMMs.
Unsupported PCI Card Detected Remove PCI Card from Slot
Audible beeps
: 2 short
Possible cause
: The PCI card installed in the slot referenced in the message is strictly not supported on
this system.
Action
: Remove the card from the slot reported in the message.
Unsupported Processor Detected System will ONLY boot ROMPAQ Utility. System Halted.
Audible Beeps
: 1 long, 1 short
Possible Cause
: Processor and/or processor stepping is not supported by the current system ROM.
Action
: Refer to the server documentation for supported processors. If a ROM version exists that supports
the processor,
1.
Power down the server.
2.
Insert a Systems ROMPAQ diskette containing the latest ROM version.
3.
Boot the system to flash the system to the latest ROM version. Allow 15 minutes for the process to
complete. Successful completion is indicated by a series of beeps of increasing pitch.
USB Tape-based One button Disaster Recovery (OBDR) drive detected.
<<Press F8 for configuration options>>
Select a configuration option:
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...