Error messages 120
2.
Be sure all drives are fully seated.
3.
Replace defective cables, drive
X
, or both.
1785-Slot X Drive Array Not Configured...
(followed by one of the following):
...(1) Run Array Configuration Utility
(2) No drives detected
(3) Drive positions appear to have changed – Run Drive Array Advanced Diagnostics if previous positions are
unknown. Then turn system power OFF and move drives to their original positions.
(4) Configuration information indicates drive positions beyond the capability of this controller. This may be due to
drive movement from a controller that supports more drives than the current controller.
(5) Configuration information indicates drives were configured on a controller with a newer firmware version.
Audible Beeps
: None
Possible Cause
: Drive array configuration not detected.
Action
:
•
Run ACU ("
Array Configuration Utility
" on page
54
).
•
Power down the system and check SCSI cable connections to be sure the drives are connected
properly.
•
Run ADU ("
Array Diagnostic Utility
" on page
63
) if previous positions are unknown. Then, turn the
system power off and move the drives to their original positions.
•
To avoid data loss, update the controller firmware to the same or later version on the original
controller ("
Firmware maintenance
" on page
65
).
1786-Disk 0 Software RAID Failure, Booting Disk 1
Audible Beeps
: None
Possible Cause
: The operating system has marked the RAID 1 bootable partition on Disk 0 as bad or
the hard drive has failed.
Action
: The system attempts to boot from Disk 1. Perform one of the following actions:
•
Replace the primary drive, if applicable, and re-mirror the data from the secondary drive.
•
Repair the logical drive. Refer to the operating system documentation.
1786-Slot 1 Drive Array Recovery Needed...
...The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z
Select F1 to continue with recovery of data to drive. Select F2 to continue without recovery of data to drive.
Audible Beeps
: None
Possible Cause
: A failed or replacement drive has not yet been rebuilt.
Action
:
•
Perform one of the following actions:
•
Press the
F1
key to continue with recovery of data to the drive. Data will be automatically
restored to drive
X
when a failed drive has been replaced, or to the original drive if it is working
again without errors.
•
Press the
F2
key to continue without recovery of data to the drive. The failed drive will not be
rebuilt and the system will continue to operate in a failed state of Interim Data Recovery Mode.
•
Replace the failed drive and press the
F1
key to rebuild the array. If the drive rebuild is not
successful or is aborted because the system rebooted before the rebuild of the drive completed,
another version of the 1786 POST error message will be displayed. Refer to the following message.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...