Error messages 111
1611-Fan x Not Present (Fan Zone I/O)
Audible Beeps
: 2 short
Possible Cause
: Required fan is not installed or spinning.
Action
:
1.
Check the fans to be sure they are working.
2.
Be sure each fan cable is properly connected, if applicable, and each fan is properly seated.
3.
If the problem persists, replace the failed fans.
1611- Power Supply Zone Fan Assembly Failure Detected. Either...
...the Assembly is not installed or multiple fans have failed.
Audible Beeps
: None
Possible Cause
: Required fans are missing or not spinning.
Action
:
1.
Check the fans to be sure they are installed and working.
2.
Be sure the assembly is properly connected and each fan is properly seated.
3.
If the problem persists, replace the failed fans.
4.
If a known working replacement fan is not spinning, replace the assembly.
1611-Power Supply Zone Fan Assembly Failure Detected. Single fan...
...failure. Assembly will provide adequate cooling.
Audible Beeps
: None
Possible Cause
: Required fan is not spinning.
Action
: Replace the failed fan to provide redundancy, if applicable.
1611-Primary Fan Failure (Fan Zone System)
Audible Beeps
: None
Possible Cause
: A required fan is not spinning.
Action
: Replace the failed fan.
1611-Redundant Fan Failure (Fan Zone System)
Audible Beeps
: None
Possible Cause
: A redundant fan is not spinning.
Action
: Replace the failed fan.
1612-Primary Power Supply Failure
Audible Beeps
: 2 short
Possible Cause
: Primary power supply has failed.
Action
: Replace power supply.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...