Error messages 77
Cache Has Been Disabled; Likely Caused By a Loose Pin on One of the RAM
Chips
Description
: Cache has been disabled due to a large number of ECC errors detected while testing the
cache during POST. This is probably caused by a loose pin on one of the RAM chips.
Action
: Try reseating the cache to the controller. If that does not work, replace the cache.
Configuration Signature is Zero
Description
: ADU ("
Array Diagnostic Utility
" on page
63
) detected that NVRAM contains a
configuration signature of zero. Old versions of the server setup utility could cause this.
Action
: Run the latest version of server setup utility to configure the controller and NVRAM.
Configuration Signature Mismatch
Description
: The array accelerator board is configured for a different array controller board. The
configuration signature on the array accelerator board does not match the one stored on the array
controller board.
Action
: To recognize the array accelerator board, run ACU ("
Array Configuration Utility
" on page
54
).
Controller Communication Failure Occurred
Description
: Controller communication failure occurred. ADU was unable to successfully issue
commands to the controller in this slot.
Action
:
1.
Be sure all cables are properly connected and working.
2.
Be sure the controller is working, and replace if needed.
Controller Detected. NVRAM Configuration not Present
Description
: EISA NVRAM does not contain a configuration for this controller.
Action
: Run the server setup utility to configure the NVRAM.
Controller Firmware Needs Upgrading
Description
: Controller firmware is below the latest recommended version.
Action
: Update the controller to the latest firmware version ("
Firmware maintenance
" on page
65
).
Controller is Located in Special "Video" Slot
Description
: Controller is installed in the slot for special video control signals. If the controller is used in
this slot, LED indicators on the front panel may not function properly.
Action
: Install the controller into a different slot, and run the server setup utility to configure NVRAM.
Then, run ACU ("
Array Configuration Utility
" on page
54
) to configure the controller.
Controller Is Not Configured
Description
: Controller is not configured. If the controller was previously configured and you change
drive locations, a problem might exist with the placement of the drives. ADU ("
Array Diagnostic Utility
" on
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...