Error messages 134
IMPORTANT:
Processor socket 1 and PPM slot 1 must be populated at all times or the server does not
function properly.
•
PPMs, except the PPM installed in slot 1
•
DIMMs, except the first bank
•
Hard drives
•
Peripheral devices
2.
Install each remaining system component, rebooting between each installation to isolate any failed
components.
3.
Clear the system NVRAM.
4.
Replace the system board.
IMPORTANT:
If replacing the system board or clearing NVRAM, you must re-enter the server serial number
through RBSU ("
Re-entering the server serial number and product ID
" on page
57
).
Message ID: 4137
Severity
: Error
Description
: The processor in slot
X
, socket
X
has corrected an excessive number of internal errors. The
system will continue to operate.
Action
: Replace the processor.
Message ID: 4140
Severity
: Warning
Description
: The system is operating with a heterogeneous processor environment.
Action
: None
Message ID: 4141
Severity
: Warning
Description
: Only
X
out of the
X
installed processors have been started by the operating system. The
system will continue to operate.
Action
: Confirm that the license agreement in use supports all of the installed processors.
Message ID: 4169
Severity
: Warning
Description
: The processor in slot
X
, socket
X
has corrected an excessive number of internal errors. The
system will continue to operate.
Action
: Replace the processor.
Message ID: 4190
Severity
: Error
Windows
®
Event Log processor error codes
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...