Error messages 129
Interconnect B Error Code
LED code:
14-1, 14-2, 14-3, or 14-4
Location:
Interconnect device - side B
Action:
Perform the following steps to resolve the problem. Stop when the problem is resolved.
1.
Press the server blade management module reset button.
2.
Reseat the interconnect device.
For more information, refer to the
HP BladeSystem Maintenance and Service Guide
on the HP
website
(
http://www.hp.com/products/servers/proliant-bl/p-class/info
).
3.
Replace the interconnect device.
For more information, refer to the
HP BladeSystem Maintenance and Service Guide
on the HP
website
(
http://www.hp.com/products/servers/proliant-bl/p-class/info
).
Interconnect Module A (10-Connector) Error Code
LED code:
15-1 or 15-2
Location:
Interconnect module - side A (10-connector)
Action:
Perform the following steps to resolve the problem. Stop when the problem is resolved.
1.
Press the server blade management module reset button.
2.
Reseat the interconnect module.
For more information, refer to the
HP BladeSystem Maintenance and Service Guide
on the HP
website
(
http://www.hp.com/products/servers/proliant-bl/p-class/info
).
3.
Replace the interconnect module.
For more information, refer to the
HP BladeSystem Maintenance and Service Guide
on the HP
website
(
http://www.hp.com/products/servers/proliant-bl/p-class/info
).
Interconnect Module A (6-Connector) Error Code
LED code:
17-1 or 17-2
Location:
Interconnect module - side A (6-connector)
Action:
Perform the following steps to resolve the problem. Stop when the problem is resolved.
1.
Press the server blade management module reset button.
2.
Reseat the interconnect module.
For more information, refer to the
HP BladeSystem Maintenance and Service Guide
on the HP
website
(
http://www.hp.com/products/servers/proliant-bl/p-class/info
).
3.
Replace the interconnect module.
For more information, refer to the
HP BladeSystem Maintenance and Service Guide
on the HP
website
(
http://www.hp.com/products/servers/proliant-bl/p-class/info
).
Interconnect Module B (10-Connector) Error Code
LED code:
16-1 or 16-2
Location:
Interconnect module - side B (10-connector)
Action:
Perform the following steps to resolve the problem. Stop when the problem is resolved.
1.
Press the server blade management module reset button.
2.
Reseat the interconnect module.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...