Error messages 108
600 Series
601-Diskette Controller Error
Audible Beeps
: None
Possible Cause
: Diskette controller circuitry failure occurred.
Action
:
1.
Be sure the diskette drive cables are connected.
2.
Replace the diskette drive, the cable, or both.
3.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
61
) and replace failed components as
indicated.
602-Diskette Boot Record Error
Audible Beeps
: None
Possible Cause
: The boot sector on the boot disk is corrupt.
Action
:
1.
Remove the diskette from the diskette drive.
2.
Replace the diskette in the drive.
3.
Reformat the diskette.
605-Diskette Drive Type Error.
Audible Beeps
: 2 short
Possible Cause
: Mismatch in drive type occurred.
Action
: Run the server setup utility to set the diskette drive type correctly.
611-Primary Floppy Port Address Assignment Conflict
Audible Beeps
: 2 short
Possible Cause
: A hardware conflict in the system is preventing the diskette drive from operating
properly.
Action
:
1.
Run the server setup utility to configure the diskette drive port address and manually resolve the
conflict.
2.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
61
) and replace failed components as
indicated.
612-Secondary Floppy Port Address Assignment Conflict
Audible Beeps
: 2 short
Possible Cause
: A hardware conflict in the system is preventing the diskette drive from operating
properly.
Action
:
1.
Run the server setup utility to configure the diskette drive port address and manually resolve the
conflict.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...