Error messages 119
1779-Slot X Drive Array - Replacement drive(s) detected OR previously failed drive(s) now
operational:...
...Port Y: SCSI ID Z:
Restore data from backup if replacement drive X has been installed.
Audible Beeps
: None
Possible Cause
: More drives failed (or were replaced) than the fault-tolerance level allows. Unable to
rebuild array. If drives have not been replaced, this message indicates an intermittent drive failure.
Action
: Be sure the system is always powered up and down correctly:
•
When powering up the system, all external storage systems must be powered up before (or at the
same time as) the server.
•
When powering down the system, the server must be powered down before powering down any
external storage systems.
1783-Slot X Drive Array Controller Failure
Audible Beeps
: None
Possible Cause
: Controller failed. If this message is displayed after Options ROMPaq is run, problems
may have occurred while attempting to flash the ROM.
Action
:
1.
Reseat the array accelerator module.
2.
Reseat the controller in the PCI slot.
3.
If the problem persists, replace the array controller.
1783-Intelligent Drive Array Controller Failure
Audible Beeps
: None
Possible Cause
: Integrated array controller firmware is corrupt, or the controller failed.
Action
:
1.
Update the controller to the latest firmware version ("
Firmware maintenance
" on page
65
).
2.
If the problem persists, replace the controller.
1784-Slot X Array Controller is in lock-up state due to a hardware configuration failure.
(Controller is disabled until this problem is resolved.)
Audible Beeps
: None
Possible Cause
: One or more hardware subsystems failed to initialize properly.
Action
: Reboot the server. If the problem still exists and a cache memory module is attached to the
controller, replace the cache memory module and reboot the server.
1784-Slot X Drive Array Drive Failure. The Following SCSI Drive(s) Should Be Replaced: SCSI
Port Y: SCSI ID Z
Audible Beeps
: None
Possible Cause
: Defective drive or SCSI cables detected.
Action
:
1.
Be sure all cables are connected properly and securely.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...