1611-CPU Zone Fan Assembly Failure Detected. Single fan...
...failure. Assembly will provide adequate cooling.
Audible Beeps
: None
Possible Cause
: Required fan is not spinning.
Action
: Replace the failed fan to provide redundancy, if applicable.
1611-Fan Failure Detected
Audible Beeps
: 2 short
Possible Cause
: Required fan is not installed or spinning.
Action
:
1.
Check the fans to be sure they are working.
2.
Be sure each fan cable is properly connected and each fan is properly seated.
3.
If the problem persists, replace the failed fans.
1611-Fan x Failure Detected (Fan Zone CPU)
Audible Beeps
: 2 short
Possible Cause
: Required fan is not installed or spinning.
Action
:
1.
Check the fans to be sure they are working.
2.
Be sure each fan cable is properly connected, if applicable, and each fan is properly seated.
3.
If the problem persists, replace the failed fans.
1611-Fan x Failure Detected (Fan Zone I/O)
Audible Beeps
: 2 short
Possible Cause
: Required fan is not installed or spinning.
Action
:
1.
Check the fans to be sure they are working.
2.
Be sure each fan cable is properly connected, if applicable, and each fan is properly seated.
3.
If the problem persists, replace the failed fans.
1611-Fan x Not Present (Fan Zone CPU)
Audible Beeps
: 2 short
Possible Cause
: Required fan is not installed or spinning.
Action
:
1.
Check the fans to be sure they are working.
2.
Be sure each fan cable is properly connected, if applicable, and each fan is properly seated.
3.
If the problem persists, replace the failed fans.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...