Error messages 98
Power Fault Detected in Hot-Plug PCI Slot x
Audible Beeps
: 2 short
Possible Cause
: PCI-X Hot Plug expansion slot was not powered up properly.
Action
: Reboot the server.
Power Supply Solution Not Fully Redundant
Audible beeps
: None
Possible cause
: The minimum power supply requirement is installed, but a redundant power supply is
missing or failed.
Action
: Do one of the following:
•
Install a power supply.
•
Replace failed power supplies to complete redundancy.
Redundant ROM Detected - This system contains a valid backup system ROM.
Audible Beeps
: None
Possible Cause
: The system recognizes both the system ROM and redundant ROM as valid. This is not
an error.
Action
: None
REDUNDANT ROM ERROR: Backup ROM Invalid. - ...
...run ROMPAQ to correct error condition.
Audible Beeps
: None
Possible Cause
: The backup system ROM is corrupted. The primary ROM is valid.
Action
: Run ROMPaq Utility ("
SoftPaqs
" on page
64
) to flash the system so that the primary and backup
ROMs are valid.
REDUNDANT ROM ERROR: Bootblock Invalid. - ...
...contact HP Representative.
Audible Beeps
: None
Possible Cause
: ROM bootblock is corrupt.
Action
: Contact an authorized service provider.
REDUNDANT ROM ERROR: Primary ROM invalid. Booting Backup ROM. -...
...run ROMPAQ to correct error condition
Audible Beeps
: None
Possible Cause
: The primary system ROM is corrupt. The system is booting from the redundant ROM.
Action
: Run ROMPaq Utility ("
SoftPaqs
" on page
64
) to restore the system ROM to the correct version.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...