Error messages 109
2.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
61
) and replace failed components as
indicated.
1100 Series
1151-Com Port 1 Address Assignment Conflict
Audible Beeps
: 2 short
Possible Cause
: Both external and internal serial ports are assigned to COM
X
.
Action
: Run the server setup utility and correct the configuration.
1600 Series
1609 - The server may have a failed system battery. Some...
...configuration settings may have been lost and restored to defaults. Refer to server documentation for more
information. If you have just replaced the system battery, disregard this message.
Audible Beeps
: None
Possible Cause
: Real-time clock system battery has lost power. The system will lose its configuration
every time AC power is removed (when the system is unplugged from AC power source) and this message
displays again if a battery failure has occurred. However, the system will function and retain
configuration settings if the system is connected to the AC power source.
Action
: Replace battery (or add external battery).
1610-Temperature Violation Detected. - Waiting 5 Minutes for System to Cool
Audible Beeps
: None
Possible Cause
: The ambient system temperature exceeded acceptable levels.
Action
: Lower the room temperature.
1610-Temperature Violation Detected. - Waiting 5 Minutes for System to Cool
...Press Esc key to resume booting without waiting for the system to cool.
WARNING: Pressing Esc is NOT recommended as the system may shutdown unexpectedly.
Audible Beeps
: None
Possible Cause
: The ambient system temperature exceeded acceptable levels.
Action
: Lower the room temperature.
1611-CPU Zone Fan Assembly Failure Detected. Either...
...the Assembly is not installed or multiple fans have failed in the CPU zone.
Audible Beeps
: None
Possible Cause
: Required fans are missing or not spinning.
Action
:
1.
Check the fans to be sure they are installed and working.
2.
Be sure the assembly is properly connected and each fan is properly seated.
3.
If the problem persists, replace the failed fans.
4.
If a known working replacement fan is not spinning, replace the assembly.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...