Error messages 116
Expansion will resume when automatic data recovery has been completed.
Audible Beeps
: None
Possible Cause
: The capacity expansion process has been temporarily disabled.
Action
: Follow the action that is displayed onscreen to resume the capacity expansion process.
1753-Slot Z Drive Array - Array Controller Maximum Operating Temperature Exceeded During
Previous Power Up
Audible Beeps
: None
Possible Cause
: Controller is overheating.
Action
: Be sure adequate system cooling and sufficient airflow across controller are available.
1768-Slot X Drive Array - Resuming Logical Drive Expansion Process
Audible Beeps
: None
Possible Cause
: Power was lost while a logical expansion operation was performed. A controller reset
or power cycle occurs while array expansion is in progress.
Action
: No action is required.
1769-Slot X Drive Array - Drive(s) Disabled Due to Failure During Capacity Expansion
...Select F1 to continue with logical drives disabled. Select F2 to accept data loss and to re-enable logical drives.
Audible Beeps
: None
Possible Cause
: Data was lost while the array was expanded; therefore, the drives have been
temporarily disabled. Capacity expansion failed due to:
•
Array accelerator or hard drive failed or was removed; expansion progress data lost
•
Expansion progress data could not be read from array accelerator
•
Expansion aborted due to unrecoverable drive errors
•
Expansion aborted due to array accelerator errors
Action
:
•
Press the
F2
key to accept the data loss and re-enable the logical drives.
•
Restore data from backup.
•
Replace drive or array accelerator, as appropriate.
1770-Slot X Drive Array - SCSI Drive Firmware Update Recommended - ...
...Please upgrade firmware on the following drive(s) using ROM Flash Components (download from
www.hp.com/support/proliantstorage): Model XYZ (minimum version = ####)
Audible Beeps
: None
Possible Cause
: Drive firmware update needed.
Action
: The indicated drives are running firmware that is known to cause intermittent problems. Update
all drives to the latest firmware version ("
Firmware maintenance
" on page
65
).
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...