Error messages 113
Audible Beeps
: None
Possible Cause
: Upgrade the Array Accelerator module to a larger size.
Action
: Migrate logical drives to RAID 0 or 1, reduce the number of drives in the array, or upgrade to a
larger-size array accelerator module.
1713-Slot Z Drive Array Controller - Redundant ROM Reprogramming Failure...
...Replace the controller if this error persists after restarting system.
Audible Beeps
: None
Possible Cause
: Flash ROM is failing. The controller detected a checksum failure, but is unable to
reprogram the backup ROM.
Action
:
1.
Update the controller to the latest firmware version ("
Firmware maintenance
" on page
65
).
2.
If the problem persists, replace the controller.
1714-Slot Z Drive Array Controller - Redundant ROM Checksum Error...
...Backup ROM has automatically been activated. Check firmware version.
Audible Beeps
: None
Possible Cause
: The controller flash operation was interrupted by a power cycle, or flash ROM is
failing. The controller detected a ROM checksum error and automatically switched to the backup ROM
image.
Action
: If this backup ROM image is a lower version than the originally running image, update the
controller to the latest firmware version.
1715-Slot X Drive Array Controller - Memory Error(s) Occurred
...Warning: Corrected Memory Error(s) were detected during controller memory self-test...
Audible Beeps
: None
Possible Cause
: The memory is beginning to fail.
Action
: If this error persists, replace the controller.
1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure SCSI: Port Y: SCSI ID
Z.
Audible Beeps
: None
Possible Cause
: A hard drive SMART predictive failure condition is detected. It may fail at some time in
the future.
Action
:
•
If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive
and restore all data afterward.
•
If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in
the array are online.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...