Error messages 93
Non-numeric messages or beeps only
Advanced Memory Protection mode: Advanced ECC
Audible Beeps
: None
Possible Cause
: Advanced ECC support is enabled.
Action
: None.
Advanced Memory Protection mode: Advanced ECC with hot-add support
Audible Beeps
: None
Possible Cause
: Advanced ECC with Hot-Add support is enabled.
Action
: None.
Advanced Memory Protection mode: Online spare with Advanced ECC
...Xxxx MB System memory and xxxx MB memory reserved for Online Spare.
Audible Beeps
: None
Possible Cause
: This message indicates Online Spare Memory is enabled and indicates the amount of
memory reserved for this feature.
Action
: None.
Advanced Memory Protection mode: Multi-board mirrored memory with Advanced ECC
...Xxxx MB System memory and xxxx MB memory reserved for Mirroring.
Audible Beeps
: None
Possible Cause
: This message indicates Mirrored Memory is enabled and indicates the amount of
memory reserved for this feature.
Action
: None.
Advanced Memory Protection mode: RAID memory with Advanced ECC
...Xxxx MB System memory and xxxx MB memory reserved for RAID.
Audible Beeps
: None
Possible Cause
: This message indicates RAID Memory is enabled and indicates the amount of memory
reserved for this feature.
Action
: None.
An Unexpected Shutdown occurred prior to this power-up
Audible Beeps
: None
Possible Cause
: The server shut down because of an unexpected event on the previous boot.
Action
: Check the System Management Log or OS Event Log for details on the failure.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...