Error messages 78
page
63
) examines each physical drive and looks for drives that have been moved to a different drive
bay.
Action
: Look for messages indicating which drives have been moved. If no messages are displayed and
drive swapping did not occur, run ACU ("
Array Configuration Utility
" on page
54
) to configure the
controller and run the server setup utility to configure NVRAM.
Do not
run either utility if you believe
drive swapping has occurred.
Controller Reported POST Error. Error Code: X
Description
: The controller returned an error from its internal POST.
Action
: Replace the controller.
Controller Restarted with a Signature of Zero
Description
: ADU ("
Array Diagnostic Utility
" on page
63
) did not find a valid configuration signature to
use to get the data. NVRAM may not be present (unconfigured) or the signature present in NVRAM may
not match the signature on the controller.
Action
: Run the server setup utility to configure the controller and NVRAM.
Disable Command Issued
Description
: The issuing of the Accelerator Disable command has disabled posted-writes. This occurred
because of an operating system device driver.
Action
: Restart the system. Run ACU ("
Array Configuration Utility
" on page
54
) to reinitialize the array
accelerator board.
Drive (Bay) X Firmware Needs Upgrading
Description
: Firmware on this physical drive is below the latest recommended version.
Action
: Update the drive to the latest firmware version ("
Firmware maintenance
" on page
65
).
Drive (Bay) X has Insufficient Capacity for its Configuration
Description
: Drive has insufficient capacity to be used in this logical drive configuration.
Action
: Replace this drive with a larger capacity drive.
Drive (Bay) X has Invalid M&P Stamp
Description
: Physical drive has invalid monitor and performance data.
Action
: Run the server setup utility to properly initialize this drive.
Drive (Bay) X Has Loose Cable
Description
: The array controller could not communicate with this drive at power-up. This drive has not
previously failed.
Action
:
1.
Be sure all cables are properly connected and working.
2.
Power down the system and attempt to reconnect data/power cable to the drive.
3.
Power up the system.
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...