Error messages 121
1786-Slot 1 Drive Array Recovery Needed. Automatic Data Recovery Previously Aborted!...
...The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z
Select F1 to retry Automatic Data Recovery to drive. Select F2 to continue without starting Automatic Data Recovery.
Audible Beeps
: None
Possible Cause
: System is in Interim Data Recovery Mode and a failed or replacement drive has not yet
been rebuilt. This message is displayed if the
F2
key was pressed during a previous boot or if the
F1
key
was pressed during a previous boot and the system rebooted before the rebuild of the drive completed.
Action
:
•
Perform one of the suggested actions:
•
Press the
F1
key to retry Automatic Data Recovery to the drive. Data will be automatically
restored to drive
X
when a failed drive has been replaced, or to the original drive if it is working
again without errors.
•
Press the
F2
key to continue without recovery of data to the drive. The failed drive will not be
rebuilt and the system will continue to operate in a failed state of Interim Data Recovery Mode.
•
If drive recovery is not successful, run ADU ("
Array Diagnostic Utility
" on page
63
) for more
information.
•
If the replacement drive failed, replace with another drive.
•
If the rebuild was aborted due to a read error from another physical drive in the array, back up
all readable data on the array, run ADU, and then restore the data.
1787-Drive Array Operating in Interim Recovery Mode...
...Physical drive replacement needed: Drive X
Audible Beeps
: None
Possible Cause
: Hard drive
X
failed or cable is loose or defective. Following a system restart, this
message notes that drive
X
is defective and fault tolerance is being used.
Action
:
1.
Be sure all cables are connected properly and securely.
2.
Test and replace defective cables.
3.
Replace drive
X
. (depending on the fault-tolerance level, all data may be lost if another drive fails).
1788-Slot X Drive Array Reports Incorrect Drive Replacement...
...The following SCSI drive(s) should have been replaced: SCSI Port Y: SCSI ID Z.
The following SCSI drive(s) were incorrectly replaced: SCSI Port y: SCSI ID z.
Select F1 to continue – drive array will remain disabled.
Select F2 to reset configuration – all data will be lost.
Audible Beeps
: None
Possible Cause
:
•
Replacement drives may have been installed in the wrong drive bays.
•
A bad power cable connection to the drive, noise on the data cable, or defective SCSI cable exists.
Action
:
•
If replacement drives are installed in the wrong bays, properly reinstall the drives as indicated and:
•
Press the
F1
key to restart the server with the drive array disabled.
•
Press the
F2
key to use the drives as configured and lose all the data on them.
•
If a bad power cable connection exists:
Содержание BL30p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant Servers Troubleshooting Guide June 2006 Fifth Edition Part Number 375445 005 ...
Страница 27: ...Diagnostic flowcharts 27 Server and p Class server blade POST problems flowchart ...
Страница 31: ...Diagnostic flowcharts 31 c Class server blade fault indications flowchart ...
Страница 68: ...Software tools and solutions 68 4 Verify the firmware update by checking the version of the current firmware ...