6.12
Troubleshooting Tips
This section covers possible causes of RMC problems and suggested solutions for them.
Table 6–5 RMC Troubleshooting
Symptom
Possible Cause
Suggested Solution
You cannot enter the
RMC from the
modem.
The RMC may be in soft bypass or
firm bypass mode.
Issue the
show com1_mode
command from SRM and
change the setting if necessary.
The terminal cannot
communicate with
the RMC correctly.
System and terminal baud rates do
not match.
Set the baud rate for the
terminal to be the same as for
the system. For first-time
setup, note that the RMC and
system default baud is 9600.
RMC will not answer
when the modem is
called.
Modem cables may be incorrectly
installed.
Check modem phone lines and
connections.
RMC remote access is disabled or
the modem was power cycled
since last being initialized.
From the local serial terminal or
VGA monitor, enter the
set
password
and
set init
commands, and then enter the
enable remote
command. (See
Section 6.7.)
The modem is not configured
correctly.
Modify the modem
initialization string according to
your modem documentation.
RMC will not answer
when modem is
called.
On DC power-up, RMC defers
initializing the modem for 30
seconds to allow the modem to
complete its internal diagnostics
and initializations.
Wait 30 seconds after powering
up the system and RMC before
attempting to dial in.
Using the Remote Management Console
6-45
Содержание AlphaServer TS15
Страница 6: ......
Страница 34: ...Figure 1 14 VGA Monitor Connected to Optional Video Card B 1 2 A MR0647 1 18 hp AlphaServer TS15 Owner s Guide ...
Страница 91: ...Figure 4 3 Removing the Top Cover A 2 1 4 5 3 MR0642 Installing and Configuring Options 4 5 ...
Страница 188: ...Figure 6 4 Setup for RMC with VGA Monitor A 1 2 B MR0626 ENET VGA 6 10 hp AlphaServer TS15 Owner s Guide ...
Страница 213: ...Figure 6 5 RMC Jumpers Default Positions Using the Remote Management Console 6 35 ...
Страница 252: ......