Alert Pending: NO
Latest Alert: AC Loss
Init String: AT&H2E0&C1&D0S0=2
Dial String: ATD915085554444
Alert String: ,,,,,,,,,,5551234
User String:
Com1 Baud:9600 Flow:SOFTWARE Mode:THROUGH Modem:DISABLED
Rmc:ENABLED
Logout Timer: 20 minutes
Voltage Status: OK
Thermal Status: OK Thermal Shutdown: Enabled
Warning Threshold: 60.00°C Fatal/Power-Down Threshold:
65.00°C
Fan Status: OK Fan Shutdown: Enabled
PCI Riser: Installed
POST DPR: OK NVRAM: OK GPIOs: OK LM75: OK
RMC>
The following sequence explains the preceding example.
n
Sets the password that is prompted for at the beginning of a modem session. The
string cannot exceed 14 characters and is not case sensitive. For security, the
password is not echoed on the screen. When prompted for verification, type the
password again.
o
Sets the initialization string. The string is limited to 31 characters and can be
modified depending on the type of modem used. Because the modem commands
disallow mixed cases, the RMC automatically converts all alphabetic characters
entered in the init string to uppercase.
p
Clears the current alert.
q
Tells the RMC not to append its own fixed flow-control and carrier-detect
commands to the user-supplied modem initialization string. Instead, these will be
included as part of the user-supplied initialization string.
\
Enables remote access to the RMC modem port by configuring the modem with the
setting stored in the initialization string once the modem is connected to the system.
]
Status of the RMC configuration.
NOTE
:
Once the RMC is configured, disconnect the VT terminal from COM1 (if present)
and connect the modem.
Using the Remote Management Console
6-23
Содержание AlphaServer TS15
Страница 6: ......
Страница 34: ...Figure 1 14 VGA Monitor Connected to Optional Video Card B 1 2 A MR0647 1 18 hp AlphaServer TS15 Owner s Guide ...
Страница 91: ...Figure 4 3 Removing the Top Cover A 2 1 4 5 3 MR0642 Installing and Configuring Options 4 5 ...
Страница 188: ...Figure 6 4 Setup for RMC with VGA Monitor A 1 2 B MR0626 ENET VGA 6 10 hp AlphaServer TS15 Owner s Guide ...
Страница 213: ...Figure 6 5 RMC Jumpers Default Positions Using the Remote Management Console 6 35 ...