Table 7–1 OCP Switches
Switch Function
X
Halt/Reset
^
System Power Switch (On/Off)
Table 7–2 OCP LED Indications
LED
Color
LED On Function
]
Green
System power is on.
\
Green
There is disk activity.
[
Amber
There is a fan fault.
Z
Amber
The system is over temperature.
Y
Amber
There is a system fault.
o
and
q
Amber/blink
in unison
RMC image is corrupted but the system is not in
emergency runtime image recovery mode or emergency
runtime image recovery mode has timed out. If recovery
has timed out, unplug the system power cord and wait
until the LED on the PCI Riser card turns off. Plug in the
power cord and try again.
Y
Z
[
Amber/blink
in unison
System is in emergency runtime image recovery mode
and is awaiting firmware update.
o
p
q
Amber
RMC has failed or the system is configured for
emergency runtime image recovery but is not powered on.
o
p
q
Amber/blink
sequentially
Firmware update is in progress.
Troubleshooting