Com1_Mode Setting Description
Through
All data passes through RMC and is filtered for the escape
sequence that is used to enter the RMC CLI.
Snoop
Data partially bypasses RMC, but RMC taps into data lines
listening for the escape sequence that is used to enter the RMC
CLI.
soft_bypass
Data bypasses RMC; however, RMC automatically switches into
Snoop Mode if the system is powered off or DCD is not
detected.
firm_bypass
Data bypasses the RMC. You cannot gain access to the RMC
CLI from this mode.
set com1_modem
The
set com1_modem
command is used to indicate whether or not modem control signals
are to be used on the external 9-pin RMC/COM1 port. The available choices are: enabled or
disabled. This variable is intended for use by the OS; it is not used by the RMC.
This command changes the setting of the SRM environment variable COM1_MODEM.
set com1_rmc
The
set com1_rmc
command is used to enable/disable the ability of the internal COM1 port
(Acer) to access the RMC command set. After issuing the command, the user is prompted
for the desired setting: enabled or disabled. This command changes the setting of the SRM
environment variable COM1_RMC.
The SRM console generally controls the setting of COM1_RMC. Under normal
circumstances, the user should not change the setting of COM1_RMC and, therefore, should
not use this command.
set dial
The
set dial
command sets the string to be used by the RMC to dial out whenever an alert
condition occurs. The string must be in the correct format for the attached modem. If a
paging service is to be contacted, the string should include the appropriate modem
commands to dial the number.
NOTE:
All lowercase characters are converted to uppercase.
Using the Remote Management Console
6-43
Содержание AlphaServer TS15
Страница 6: ......
Страница 34: ...Figure 1 14 VGA Monitor Connected to Optional Video Card B 1 2 A MR0647 1 18 hp AlphaServer TS15 Owner s Guide ...
Страница 91: ...Figure 4 3 Removing the Top Cover A 2 1 4 5 3 MR0642 Installing and Configuring Options 4 5 ...
Страница 188: ...Figure 6 4 Setup for RMC with VGA Monitor A 1 2 B MR0626 ENET VGA 6 10 hp AlphaServer TS15 Owner s Guide ...
Страница 213: ...Figure 6 5 RMC Jumpers Default Positions Using the Remote Management Console 6 35 ...
Страница 252: ......