Glitch trigger mode
is indicated
by a positive or negative pulse on the
status line. In glitch capture mode,
the oscilloscope uses memory re-
sources to record an event where at
least two transitions occurred be-
tween sample periods. The
oscilloscope can capture pulses as
narrow as 3.5 ns and as long as the
sample period—1 ns at any sweep
speed.
HF Reject
(high-frequency reject)
adds a low-pass filter with a 3 dB
point at 50 kHz to the trigger path.
Holdoff
keeps the trigger from re-
arming for an amount of time set by
the holdoff knob.
Horizontal controls
adjust the
time base, horizontal mode, and de-
layed sweep functions.
Invert
shifts the displayed wave-
form 180 degrees, and is available for
channels 1 and 2. When the oscillo-
scope is triggered on the signal to be
inverted, the trigger is also inverted.
Level
changes the trigger level.
LF Reject
(low-frequency reject)
adds a high pass filter with a 3 dB
point at 50 kHz to the trigger path.
Line
in TV trigger mode, the oscil-
loscope triggers on the TV line sync
pulses. As a trigger source, the oscil-
loscope triggers off of the power line
frequency.
Main/Delayed
allows you to select
the horizontal mode (Main, Delayed,
XY, and Roll), and set the vernier
and time reference.
Measurement algorithms
are
used to calculate input frequency, in-
put period, duty cycle, positive and
negative widths on logic channels,
and rise time and fall time.
Measurement field
is used to dis-
play results for measurements,
trigger settings, error messages, and
status messages.
MegaZoom technology
is HP’s
technology that combines the advan-
tages of conventional deep-memory
digital oscilloscopes with the respon-
siveness and update rate of
traditional analog oscilloscopes. See
the chapter “MegaZoom Concepts
and Oscilloscope Operation” for
more information.
Mode/Coupling
allows you to se-
lect a trigger mode (Auto level,
Auto, Normal), Coupling, Reject, and
Noise Reject.
Glossary
Glossary-6
Содержание 54645A
Страница 5: ...iv ...
Страница 12: ...1 Getting Started ...
Страница 17: ...Items Supplied with the HP 54645A D Oscilloscopes Figure 1 3 Getting Started Check package contents 1 6 ...
Страница 18: ...Optional Accessories for the HP 54645A D Oscilloscopes Figure 1 4 Getting Started Check package contents 1 7 ...
Страница 25: ...1 14 ...
Страница 26: ...2 Front Panel Overview ...
Страница 60: ...3 Triggering HP 54645A D Oscilloscopes ...
Страница 84: ...4 MegaZoom Concepts and Oscilloscope Operation ...
Страница 142: ...5 Making Measurements with HP 54645A D Oscilloscopes ...
Страница 176: ...6 Using Option 005 Enhanced TV Video Trigger HP 54645A ...
Страница 189: ...6 14 ...
Страница 190: ...7 Testing Adjusting and Troubleshooting ...
Страница 242: ...8 Replacement Parts ...
Страница 254: ...Exploded View of HP 54645A D Oscilloscope Figure 8 3 Replacement Parts To order a replacement part 8 13 ...
Страница 259: ...8 18 ...
Страница 260: ...9 Performance Characteristics ...
Страница 271: ...9 12 ...
Страница 272: ...10 Messages ...