E3 Series Installation/Operation Manual
—
P/N 9000-0574:I 11/04/10
19
Section 2: Installation
2.1 General
The E3 Series
®
System is a modular system and is shipped unassembled. The backbox, doors, and
sub-assemblies are individually packaged and can be easily assembled.
2.2 Installation Requirements
All components of the E3 Series
®
System should be located per the following requirements:
•
Installations are to be indoors only, in dry lo
cations, protected from rain, water, and rapid
changes in temperature that could cause condensation. Equipment must be securely mounted
on rigid, permanent walls.
•
Operating temperature shall not exceed the
range of 32
° to 120°
F (0 to 49
° C).
•
Operating humidity not to exceed 93%
non-condensing at 90
° F (32° C).
•
There should be adequate space around the installation to allow easy access for operation and
servicing.
•
All sub-assemblies and components are to be
located in compliance with local and national
codes.
•
All installation field wiring shall be in compliance with local and national codes.
2.3 Unpacking and Inspecting Components
Remove all sub-assemblies and accessories from their shipping cartons to access the enclosure.
Remove and inspect the enclosure for shipping damage. Inspect all electronic sub-assemblies for
damage without removing them from their anti-static protective bags. If any pieces are found
damaged, notify the shipping carrier immediately. Report missing components to the Gamewell-
FCI Customer Service.
2.4 Mounting Sub-assemblies
1.
The ILI-MB-E3, ILI95-MB-E3 and/or ANX consist of a main operating board with pluggable
terminal strips. Install this sub-assembly immediately unless any optional units are to be used
in the system. Refer to the Installation Instructions P/N 9000-0579, P/N 9001-0017 and 9001-
0064. Before installing the ILI-MB-E3, ILI95-MB-E3 and/or ANX into the system backbox,
refer to the Installation Instructions shipped with each sub-assembly for the proper procedures:
2.
Install the door after the sub-assemblies are in place. Note that the door can only be installed
(or removed) when it is opened at least 90
° from the backbox.
Содержание Gamewell-FCI E3 Series
Страница 95: ...94 E3 Series Installation Operation Manual P N 9000 0574 I 11 04 10 Installation Cabinets Notes ...
Страница 172: ...E3 Series Installation Operation Manual P N 9000 0574 I 11 04 10 171 Analog Sensors E3 Series System Connections Notes ...
Страница 179: ...178 E3 Series Installation Operation Manual P N 9000 0574 I 11 04 10 Programming INFO Menu Selection Notes ...
Страница 185: ...184 E3 Series Installation Operation Manual P N 9000 0574 I 11 04 10 Notes ...
Страница 189: ...Gamewell FCI 12 Clintonville Road Northford CT 06472 1610 USA 203 484 7161 fax 203 484 7118 www gamewell fci com ...
Страница 190: ...CFI Security Inc 1845 Northwestern Suite B El Paso Texas 79912 Ph 915 778 6061 Fax 915 778 7046 ...