Precision Platform 4022 Scanner
Cable End Electrical Assemblies and Precision Measurement Processor
10/18/07
p/n
6510020208
6-32
6.6.2.1.
Computer/Manual switch S1
In
Computer
mode, the MSS control algorithms handle the movement of
the heads.
On the Termination Board, S1 switches between
Computer
and
Manual
mode. In
Manual
mode, pushbuttons S2 and S3, or
SCAN/OFFSHEET
buttons control head movement.
6.6.2.2.
Scan/Forward switch S2
S2 is the
SCAN/FORWARD
button on the Termination Board.
In
Computer
mode, pressing the
SCAN/FORWARD
button serves the
same function as the
SCAN
button on the tending end support (that is, it
instructs the MSS to begin normal scanning).
In
Manual
mode, pressing the
SCAN/FORWARD
button starts the
scanner moving toward the drive end support at a rate set by the speed
potentiometer on the Frame Controller PCB.
6.6.2.3.
Offsheet/Reverse switch S3
S3 is the
OFFSHEET/REVERSE
button on the Termination Board.
In
Computer
mode, pressing the
OFFSHEET/REVERSE
button serves the
same function as the
OFFSHEET
button on the tending end support (that
is, it instructs the MSS to stop scanning and move to the offsheet position).
In
Manual
mode, pressing the
OFFSHEET/REVERSE
button starts the
scanner moving toward the cable end support at a rate set by the speed
potentiometer on the Frame Controller PCB.
6.6.2.4.
Frame Controller switches
On the Frame Controller Board, there is a toggle switch that has a
Host/Shop mode position. When the switch is in the
Host
mode, scanner
movement is controlled by the host computer. When in the
Shop
mode,
scanner movement is controlled by the Frame Controller. The scan speed
in this mode depends on the adjustment of potentiometer R16 on the
Frame Controller.
Содержание 4022
Страница 1: ...Precision Platform 4022 Scanner System Manual 6510020208 ...
Страница 2: ......
Страница 3: ...Precision Platform 4022 Scanner October 2007 ...
Страница 22: ......
Страница 72: ......
Страница 94: ......
Страница 126: ......
Страница 162: ......
Страница 170: ......
Страница 221: ...Scanner Maintenance Heads and sensors Figure 9 10 High Pressure Air Manifold p n 6510020208 10 18 07 9 45 ...
Страница 234: ......
Страница 239: ...Glossary p n 6510020208 10 18 07 11 5 VIO Virtual Input Output ...