Precision Platform 4022 Scanner
Cable End Electrical Assemblies and Precision Measurement Processor
10/18/07
p/n
6510020208
6-14
Switches Termination
Board
(4022-30 and 4022-31)
S1
Up: Manual mode
Down: Computer mode
S2
Computer mode: Scan
Manual mode: Forward
S3
Computer mode: Offsheet
Manual mode: Reverse
Table 6-5 Termination Board Fuses
Fuse Termination
Board
(4022-30 and 4022-31)
F1
6A - 24V electric
F2
6A - 24V solenoid
F3
10A - 24V Auxiliary
F4
10A - 24V electric; Upper power track
F5
10A - 24V electric; Lower power track
F6
10A - 24V solenoid; Upper power track
F7
10A - 24V solenoid; Lower power track
6.3.1.2.
Termination board connectors and signals
There are several connectors on the Termination PCB. Many of the
connectors are of different types, reducing the possibility that a cable will
be installed incorrectly. Table 6-6 details all of the signals connected to the
Termination PCB except for the power track.
Table 6-6 Termination PCB signals
Terminal Termination
Board
(4022-30 and 4022-31)
AC Power
J9-1
56 VAC Air Gap & Trim
J9-2
56 VAC Air Gap & Trim
J9-3
56 VAC Air Gap & Trim
J9-4
56 VAC Air Gap & Trim Return
J9-5
56 VAC Air Gap & Trim Return
J9-6
56 VAC Air Gap & Trim Return
J9-7
56 VAC Sheet Guide
Содержание 4022
Страница 1: ...Precision Platform 4022 Scanner System Manual 6510020208 ...
Страница 2: ......
Страница 3: ...Precision Platform 4022 Scanner October 2007 ...
Страница 22: ......
Страница 72: ......
Страница 94: ......
Страница 126: ......
Страница 162: ......
Страница 170: ......
Страница 221: ...Scanner Maintenance Heads and sensors Figure 9 10 High Pressure Air Manifold p n 6510020208 10 18 07 9 45 ...
Страница 234: ......
Страница 239: ...Glossary p n 6510020208 10 18 07 11 5 VIO Virtual Input Output ...