[1]
STARTER
CABLE 1P
CONNECTOR
(W WIRE)
[2]
CONNECTOR
BRACKET C
[3]
STARTER CABLE
[4] HARNESS
CLIP (2)
18-18
[1] 8 mm WASHER-
NUT
[1]
8 mm WASHER-
NUT
[6] ALTERNATOR
FUSE CABLE
[6]
ALTERNATOR
FUSE CABLE
[5] 8 mm WASHER
[4]
STARTER
CABLE (+)
[4]
STARTER CABLE (+)
[3]
B TERMINAL
90˚
[2]
TERMINAL COVER
5) Install the positive (+) starter cable on the magnetic switch
B terminal at right angles to the vertical center line of the
magnetic switch as shown. Tighten the 8 mm washer-nut to
the specified torque.
TORQUE: 11 N.m (1.1 kgf.m, 8 lbf.ft)
After tightening, set the 8 mm washer on the magnetic
switch B terminal.
6) Install the alternator fuse cable on the magnetic switch B
terminal at right angles to the vertical center line of the
magnetic switch as shown. Tighten the 8 mm washer-nut to
the specified torque.
TORQUE: 11 N.m (1.1 kgf.m, 8 lbf.ft)
After tightening, set the terminal cover on the magnetic
switch B terminal.
7) Connect the starter cable 1P connector (White wire).
8) Set the starter cable 1P connector (White wire) on the
connector bracket C.
9) Secure the starter cable with the two harness clips.
10) Install the following parts.