BF135A•BF150A
5-137
7) Disconnect the pressure regulator control tube and the pres-
sure regulator return hose from the pressure regulator.
8) Remove the pressure regulator. Remove the joint pipe and
the O-rings.
• Replace the O-rings on assembly.
9) Remove the 6 x 25 mm flange bolt and remove the fuel
hose (high pressure side).
10) Remove the joint pipe and the O-rings.
• Replace the O-rings on assembly.
11) Release the fuel tube (2 places) and the air vent tube (2
places) from the 14 mm fuel tube clips.
12) Remove the two 6 mm flange nuts and remove the fuel line
assembly.
[1] AIR VENT TUBE
[2] PRESSURE REGULATOR
CONTROL TUBE
[3] 8 mm FLANGE NUT (2)
[4]
14 mm FUEL
TUBE CLIP
[5] FUEL TUBE
[3]
FUEL HOSE
(HIGH PRESSURE
SIDE)
[2]
FUEL LINE
ASSEMBLY
[4] O-RING (2)
Do not reuse.
[2] O-RING (2)
[5] JOINT PIPE
[1]
JOINT PIPE
6 x 25
[3]
PRESSURE
REGULATOR
[6]
PRESSURE
REGULATOR
RETURN
HOSE
[1]
TUBE CLAMP
D10.7
Do not reuse.