Spacer for transducers adjustment # EAA0470G84A.
Use this tool to make the mechanical preloading of both transducers
Snap-on QDRIVER 4NM / 2.95lbsft
Use this torque wrench on ALLOY vibratory system only to proper tighten
transducers screws.
Sonar Calibration Tool # EAA0344G09A
This tool allows a high accuracy sonar sensor calibration.
Use this calibration tool to calibrate (C82) the sonar sensor. It is required after:
Ø
Sonar sensor replacement
Ø
BP box replacement
Ø
Distance and/or diameter potentiometer/s replacement
Ø
Vibratory assy replacement.
Ø
Wheel guard replacement
Electronic inclinometer and spirit level