116
8.
Once the laser dot is adjusted to the correc place press the button “OK to store the inner laser position.
9.
Then the laser dot will move to the outer plane.
10. Repeat the same procedure as described above from point 7, to adjust
the laser dot position.
11. Once the laser dot is adjusted to the correct place press the button “OK” to store the outer laser
position.
12. Press “STOP” button to exit the service code.
Comments
:
The setting can be stored to persistent memory by performing code C90.
C123
Laser pointer: Display of the status and execution of diagnostic tests
Options:
None
Special function:
None
Description:
A numeric sequence of 4 numbers that have the following meaning is displayed.
0 : off (fail)
1 : on (ok)
Once selected C123, the following display is displayed
0/1
0/1
0/1
0/1
Main board power
Motor stream
Laser stream
Zero mark
SM HOF GEODYNA 7600 Rel.D