79
5.9 EEP CODES
The beeps codes are made to recognize the malfunction of the machine in case of screen problem.
5.9.1 ABBREVIATIONS
Beeps
*
Frequency
: 2000 Hz
Duration
: 100 ms
Pause
: 100 ms (Pause after beep, total length = 200 ms)
S
Frequency
: 1600 Hz
Duration
: 200 ms
Pause
: 400 ms
L
Frequency
: 1600 Hz
Duration
: 500 ms
Pause
: 400 ms
nS or nL
n
repeats of
S
or
L
Pause
Pn
Duration
: n seconds
5.9.2 BEEP SEQUENCES
A beep sequence consists of a
Ø
- A - :
Prefi x beep
Ø
- B - :
Beeps which indicates the initialisation step
Ø
- C - :
Beeps which indicates the module/object
Ø
- D - :
Pause between the cycle
5.9.3 –A- PREFIX BEEP
Each beep will be indicated by a prefi x beep
Ø
P0.5
5.9.4 -B- BEEPS OF THE INITIALISATION STEP
Beep sequence Description
ID MODULE
S P1
Error during basic initialisation:
I2C bus (Keyboard, keyboard cable)
22
Message server
83
Command language
81
S S P1
Error during PO (persistent objects) based initialisation:
Encoder board of main shaft
29
External AD converter
25
Internal AD converter
26
Temperature sensor measurement
27
Data conditioning
42
S S S P1
Extensions, based on Pos:
Keyboard/display, SAPE, brake, motor
44, 45, 46, 47, 48
Drive system
49
SM HOF GEODYNA 7600 Rel.D